Notice: Our Sales Office Will Be Closed From Friday March 29th Through To Monday April 1st. Deliveries Will Commence As Normal From Tuesday April 2nd. Happy Easter!

✆ Call us at 020 3936 2839      |      

Catnic Extra Heavy Duty Open Back Cavity Wall Lintel - CX90/125

SKU
CX90/125
  • Product Applications: For 90-105mm Cavity, 125-140mm Wide Inner Leaf
  • Triangulated masonry load
  • Supporting uniformly distributed masonry load
  • Supporting uniformly distributed timber floor and roof loads
  • Suitable for fair faced inner leaf masonry
  • Supports concrete floors
Delivery: Estimated at 3-4 Weeks more details
Only %1 left
Product Information

Catnic Extra Heavy Duty Open Back Cavity Wall Lintel - CX90/125

Benefits:

  • Easy-to-use open back profile: Allows masonry to be built up continuously on both outer and inner leaf
  • Materials used in Lintels: The CG, CH and CX ranges are formed from galvanised steel, then powder coated
  • Duplex corrosion protection: Ensures optimum durability and longevity
  • Built-in DPC: Saves time in construction and means cavity is easy to clean without risk of damage to DPC
  • Integral Plaster key: With staggered slots applied to the inner flange and ribbed underside of insulation (perforated steel baseplate on CH and CX range)
  • Continuous insulation: Maximising thermal efficiency, minimising cold bridging
  • Product Applications: For 90-105mm Cavity, 125-140mm Wide Inner Leaf

Features:

  • Triangulated masonry load
  • Supporting uniformly distributed masonry load
  • Supporting uniformly distributed timber floor and roof loads
  • Suitable for fair faced inner leaf masonry
  • Supports concrete floors
  • Attic truss loads
  • Larger span multiple truss loads

Conditions of use:

  • Nominal 150mm end bearings
  • Both leaves are raised together
  • One course of block prior to installation of floor/roof
Standard Lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 17.2 17.2 20.9 20.9
Nominal height'h' (mm) 232 232 232 232

Note:

  • Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm - 4800mm (including 4575 but excluding 4500mm).
  • The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
  • To achieve the CH & CX loading figures indicated, lintels must be built-in as illustrated, ensuring that the blockwork infill is well-jointed during construction and compatible with the strength of thr masonry above.
  • When using the Catnic CH and CX Open Back ranges with concrete floors, always ensure that the blockwork is built tight against the inner vertical face, and that a mortar joint is added to the top of the blockwork so that the floor units have an even spread over the inner flange of the lintel.